“IN THE HEADLIGHTS”
New Mexico Trucking Association - February 23, 2011
Fraudulent letters claiming to be from the DOT
Read the full document (64.4 KB)
Handrail dislodged from stand resulting in dropped object
Unknown Co. - March 22, 2010
During operation of a centrifuge pump, a handrail was vibrated out of its holding position and fell approx 10 ft. into the cement pond.
Read the full document (405.5 KB)
Vacuum Truck Fatality
Unknown Co. - March 22, 2010
While duping the contents of a hydrovac unit, a swamper was killed when he was caught in the closing hydrovac tank door.
Read the full document (127.55 KB)
Flash Fire DAFW Case
Unknown Co. - January 7, 2010
IP did not recognize the potential hazard of gas accumulating on the compressor skid and creating a flammable mixture
Read the full document (4.57 MB)
Brake Linkage Failure
Unknown Co. - August 31, 2009
Brake linkage rod failed between the brake handle and the pillar block.
Read the full document (514.5 KB)
Dropped Pipe Lessons Learned
Unknown Co. - August 17, 2009
Whilst carrying out normal pulling out of the hole drilling operations a full stand of 3.5 inch drill pipe (93 ft, 1237 lb) came free from the top drive elevators and fell across the drill floor onto the derrick steelwork and over the rig floor hand rails, coming to rest on the concrete rig pad, approximately 30 ft below the drill floor and laying across the derrick structure cross member. Location: Algeria
Read the full document (167 KB)
Overhead Transmission Line Strike
Unknown Co. - August 14, 2009
On 31 March 2009, at approximately 1200 hours, an incident occurred on a BP well site lease road that resulted in potential exposure to electrical current from an overhead transmission line.
Read the full document (102.24 KB)
Amputation of Fingers While Handling Pipe
Unknown Co. - August 10, 2009
Pipe pulled off from the I-beam which cause the fingers caught between the beveled edge of the pipe and the I-beam which resulted amputation of 4 fingers.
Read the full document (165.14 KB)
Little Finger Could this Happen in your OC?
Unknown Co. - August 7, 2009
IP was responding to an air compressor alarm found primary air compressor locked up.
Read the full document (226.5 KB)
SPD WE HIPO & Lateral Learning Bulletin
Unknown Co. - August 6, 2009
During running a completion the Weatherford Power tong (JAM unit) got stuck on the pipe when making up a pup joint. After manual attempts to free the power tong from the pipe the hydraulic piston to adjust height position of power tong was used for extra vertical force. The extra force on the cable caused the bracket with sheave wheel to fail catastrophically. Bracket + wheel dropped to the floor from appr. 20 m. whilst 5 workers where on the floor. Nobody got injured. The power tong was still attached to the pipe after the incident, did not drop to the floor.